Appliance Energy Cost Calculator

Air conditioner running cost

With example figures of 1,000 W of electrical input, 8 hours of use and $0.20 per kWh, an air conditioner (air conditioning or aircon) uses 8 kWh and costs $1.60, an upper-end figure because the compressor cycles on and off. Enter your unit's rated input in watts (not its cooling capacity) below.

Calculator

Required to add it to your comparison, where it is used as the name. It does not fill in any values.

Rated input power from the label or manual. Appliances that cycle on and off use less on average.

On a day the appliance is used. Up to 24.

Up to 7.

Your own assumption. 100% means full rated input for every hour entered. Lower it only if you know the unit cycles off.

Electricity price

From your bill or supplier. Use the price per kWh, for example 0.15.

Changes the currency symbol only. No exchange rates are applied.

How to find your price on your bill
  • Where your bill shows them, add up the charges billed per kWh, such as supply (or generation) and delivery. These are the charges that grow when an appliance runs.
  • Leave out fixed monthly charges, such as a customer or service charge. They generally stay the same however much electricity you use.
  • If the price is in cents, divide by 100: 15.5¢ per kWh is 0.155.
  • Only a total amount and total kWh? Dividing the amount by the kWh gives a rough all-in average. Because it includes fixed fees and taxes, it may overestimate the extra cost of running an appliance.
  • If your price changes by time of day or with how much you use, enter the price that applies to most of your use.

For comparison, the U.S. Energy Information Administration publishes average electricity prices by state. Your own bill gives a closer estimate.

Fill in the fields above to see your estimate.

Estimated results

Fill in the fields to see the estimated energy use and cost.

How many weeks a year you run it. The Year row above assumes use all year.

This season estimate is a separate figure shown on this page only. It does not change what is saved when you add the air conditioner to your comparison: comparison and dashboard figures use year-round use (every week of a 365-day year).

How much does it cost to run an air conditioner per hour?

It depends on the unit's electrical input, how much of each hour the compressor actually runs and your electricity price. With those figures:

  • cost per hour: input watts × effective power % ÷ 100 ÷ 1,000 × your price per kWh;
  • cost per day of use: the hourly cost × the hours you run it;
  • cost per season: the weekly cost × the weeks you use it.

The calculator above shows each of these, starting from full rated input (100%), which is an upper-end figure. If you only know the cooling capacity, use the capacity and efficiency ratio estimate below.

Use electrical input, not cooling capacity

Cooling capacity, given in BTU/h or sometimes in kW, describes how much heat the unit removes. It is not the electricity it uses. Look for the rated electrical input power in watts on the nameplate, in the manual or in the specifications. If the label lists only volts and amps, multiplying them gives volt-amperes, which can be higher than the real power, so treat the result as an upper estimate.

Only know the capacity and efficiency ratio?

Some labels and listings give the cooling capacity in Btu/h and an efficiency ratio, but not the electrical input. A ratio such as the combined energy efficiency ratio (CEER) is defined in Btu per watt-hour, so dividing the capacity by the ratio gives an approximate input in watts: Btu/h ÷ Btu/Wh = W. CEER also counts standby and off-mode energy, so the result is an approximation; the rated input on the nameplate is better when you have it.

From the label or specifications, in Btu/h.

In Btu per watt-hour, such as CEER, from the label or specifications.

Enter both figures to estimate the electrical input.

Illustrative example: a unit rated at 12,000 Btu/h with a ratio of 10 Btu/Wh gives about 12,000 ÷ 10 = 1,200 W. Do not use the EU seasonal ratios (SEER and SCOP) this way: they describe performance over a whole season, and the EU label already gives the annual energy consumption in kWh.

Window, portable and central air conditioners

The calculator works the same way for each type. What differs is where you find the electrical input:

  • Window and portable units plug into a socket. The nameplate or manual gives the rated input in watts, or the volts and amps. A plug-in energy monitor can measure them, if the plug and the monitor's rating allow it.
  • Central (ducted) systems have an outdoor unit and an indoor fan, and are usually wired in rather than plugged in, so a plug-in monitor cannot measure them. Use the electrical input of both parts where the specifications list it. If a nameplate gives only volts and amps, the volts and amps helper gives an upper estimate. Comparing your meter readings with the system on and off is another option; see how to measure real appliance electricity use.

In every case, enter electrical watts, never the cooling capacity in BTU/h.

How much does it cost per month?

The Average month row is the year ÷ 12, so it assumes use all year round. For a month in which you run the unit every day, multiply the weekly figure by 365 ÷ 7 ÷ 12, about 4.35 weeks. Illustrative example: a 1,000 W unit at full rated input, 8 hours a day, at $0.20 per kWh uses 1 kWh an hour ($0.20), 8 kWh a day ($1.60) and 56 kWh a week ($11.20), or 56 × 365 ÷ 7 ÷ 12 = 243.33 kWh in a month of daily use, costing $48.67. The 1,000 W and $0.20 are example figures, not a typical unit or price.

The effective-power assumption

A thermostat switches the compressor on and off, and inverter units vary their power, so an air conditioner does not always draw its full rated input. The calculator starts at 100%, which assumes full rated input for every hour entered and gives an upper-end estimate. Lower it only if you have a reason, such as readings from a plug-in energy monitor. No typical percentage is suggested, because it depends on your climate, insulation, temperature setting and unit size. To work out a percentage from a measurement, see how to measure real appliance electricity use. What affects how much electricity an air conditioner uses explains the conditions that change it.

Seasonal use

The Year row assumes the unit runs every week of the year. Enter your weeks of use per year to see a season estimate. Appliances added to your comparison and dashboard keep the year-round convention.

What air conditioner labels tell you

  • United States: the EnergyGuide label for room air conditioners shows an estimated yearly energy cost, the model's energy use and efficiency rating, and its capacity. The rule bases the cost on a national average electricity cost and seasonal use of 8 hours a day over 3 months.
  • Canada: room and portable air conditioners must carry an EnerGuide label showing annual energy consumption in kWh.
  • European Union: the label shows the design load in kW, the seasonal energy efficiency ratio (SEER) and the annual energy consumption for cooling in kWh per year, with separate heating figures for up to three European heating seasons.
  • Australia and New Zealand: air conditioners can carry a Zoned Energy Rating Label.

Efficiency ratios such as SEER compare cooling output with electricity input. They are useful for comparing models but cannot be entered as watts. A label's yearly kWh can be used with the energy per year method of the appliance cost calculator, but it reflects the label's assumed hours and climate, not yours. More on each label: how to read appliance energy labels.

Limitations

  • This is an estimate from the figures you enter, not a measurement of your unit.
  • At 100% effective power it is an upper-end estimate for the hours entered.
  • It does not model outdoor temperature, insulation, room size or the thermostat setting.
  • Heating mode on a reverse-cycle unit can draw a different power; estimate it separately.

Illustrative example

An illustrative 1,000 W input used 8 hours a day, 7 days a week, at 100% uses 8 kWh per day of use and 56 kWh a week. At an illustrative $0.20 per kWh that is $11.20 a week, or $134.40 over a 12-week season. If you assumed 60% effective power instead, every figure would be 60% of these.

Frequently asked questions

Can I convert BTU/h to watts and enter that?

Not directly. Converting BTU/h to watts on its own gives the cooling output in different units, not the electricity the unit uses. Use the rated electrical input from the nameplate or manual, or divide the capacity by an efficiency ratio in Btu per watt-hour with the estimate above.

Should I lower the effective power?

Only with a reason, such as a measurement. Without one, 100% gives an upper-end figure that you know is not an underestimate for the hours entered.

Why does the dashboard show a full year?

Comparison and dashboard figures use year-round use, so every appliance is compared on the same basis. Use the season estimate on this page for the weeks you actually run it.

Does a warmer thermostat setting lower the cost?

It can. The U.S. Department of Energy says you can save as much as 10% a year on heating and cooling by turning your thermostat back 7–10°F for 8 hours a day from its normal setting; for cooling, that means a warmer setting. The calculator cannot predict that saving for your home. To compare, run two estimates with fewer hours or a lower effective power, ideally based on measured use before and after the change.

Is it cheaper to turn the air conditioner off when I go out?

Hours when the compressor is not running use less electricity, which is consistent with the Department of Energy's setback guidance above. How much you save depends on your home, climate and unit. Enter the hours you actually run it, or compare two estimates with different hours.

Sources

These sources support specific statements on this page. They do not review or endorse this calculator or its results. Last reviewed .