What affects how much electricity an air conditioner uses
An air conditioner's electricity use depends on its electrical input, how long the compressor actually runs and how hard it has to work. The set temperature, the heat outside, the sun, the size of the unit and the state of its filters all change that, so the same unit can use very different amounts on two days.
Published
Cooling capacity is not electrical power
An air conditioner has two different power figures, and only one belongs in a cost estimate.
- Cooling capacity, in BTU per hour or kW of cooling, is how fast it can remove heat. Natural Resources Canada defines it as the maximum rate at which the unit can remove heat from the space. A “ton” of capacity is 12,000 BTU/h, or 3.5 kW of cooling.
- Electrical input, in watts, is what it draws from the supply. This is the number that turns into kWh on your meter.
The two are linked by efficiency ratings. The EER (energy efficiency ratio) is the cooling capacity in BTU/h divided by the electrical input in watts, at set test conditions; a higher EER means more cooling per watt. The SEER measures efficiency over a whole cooling season rather than at one condition, and the CEER, defined in Canada's regulations for room air conditioners, also counts the power used when the unit is not cooling. Entering a 12,000 BTU/h capacity as 12,000 watts would treat a rate of cooling as electrical power and give a meaningless result, so look for the input watts on the rating plate. If you only have the capacity and the EER, the air conditioner calculator can estimate the watts from them.
Because EER = capacity ÷ input watts, the input is the capacity divided by the EER. For an illustrative unit with a capacity of 12,000 BTU/h and an EER of 12, that is 12,000 ÷ 12 = 1,000 W, so an hour with the compressor running at that rating uses 1,000 × 1 ÷ 1,000 = 1 kWh. Both figures are examples for the arithmetic, not typical values, and an EER describes one test condition, so use the input watts on the rating plate when you have them.
Fixed-speed and inverter compressors
A fixed-speed (on/off) unit runs its compressor at one speed. When the room warms above the set point, the compressor starts; when it is cool enough, it stops. Over an evening it cycles on and off, drawing much more while the compressor runs than while only the fan is running.
A variable-speed or inverter unit slows its compressor down instead of stopping it, so once the room is cool it can keep running at a lower power. ENERGY STAR recommends variable-speed compressors for better efficiency. Even so, the energy any unit uses depends on how much cooling the room needs, so an inverter unit is not guaranteed to use less in every situation, and its rated input is not what it draws every hour.
What makes it work harder
The set temperature
The cooler you ask the room to be, the more heat the unit has to remove and the longer it runs. Natural Resources Canada advises the highest thermostat setting that is still comfortable, and ENERGY STAR suggests setting it as high as is comfortable, typically 78°F (about 26°C). The U.S. Department of Energy notes that a ceiling fan lets you raise the setting by about 4°F without feeling less comfortable.
Heat and humidity outside
On a hotter day more heat comes in through the walls, roof and windows, and the unit has to push its heat out into hotter air. Natural Resources Canada lists the weather and local climate among the factors that change operating cost. Air conditioners also dry the air as they cool it, so humid weather adds to the work.
The sun
Sunlight through windows heats a room directly. Natural Resources Canada suggests awnings, blinds or drapes to keep direct sun out of the living space.
Insulation, gaps and open doors
Heat that leaks in has to be removed again. Natural Resources Canada recommends sealing air gaps and insulating the attic and walls, and lists how often and how long doors and windows are open as a factor in running cost. ENERGY STAR notes that an improperly installed room unit can leak a lot of air around it.
Size
Bigger is not better. ENERGY STAR advises sizing a unit to the space it cools, and both ENERGY STAR and Natural Resources Canada explain that an oversized unit cools the room in short cycles before it has removed the humidity, which is less efficient and less comfortable. An undersized unit may run flat out for hours without reaching the set temperature.
Filters and upkeep
A dirty filter restricts the airflow. Natural Resources Canada recommends cleaning room air conditioner filters at least once each season, and the Department of Energy suggests cleaning or replacing filters monthly or as the maker recommends. Keep the outdoor part of a split or central system clear of leaves and debris.
How long the compressor runs
The hours a unit is switched on are not the hours its compressor runs at full power. Natural Resources Canada notes that heavily used room units run three or four times as many hours as seldom-used ones, which shows how much habits matter. For an estimate, think about the hours you use it each day, how much of that time the compressor works hard, and whether the room needs cooling all that time.
Two ways to estimate the cost
Both examples use an illustrative unit with an electrical input of 1,500 W, used 8 hours a day, at an illustrative price of $0.20 per kWh. These are not typical values; use your own unit's input, your hours and your price. As in the calculator, an average month is a twelfth of a 365-day year.
| Assumption | Per hour | Per day | Per average month |
|---|---|---|---|
| Full input the whole time (100%) | 1.5 kWh$0.30 | 12 kWh$2.40 | 365 kWh$73.00 |
| Effective power 60% | 0.9 kWh$0.18 | 7.2 kWh$1.44 | 219 kWh$43.80 |
- Full input: 1,500 × 1 ÷ 1,000 = 1.5 kWh an hour, costing $0.30; 1.5 × 8 = 12 kWh a day, costing $2.40; 12 × 365 ÷ 12 = 365 kWh in an average month, costing $73.00.
- At 60% effective power the average draw is 1,500 × 0.6 = 900 W: 0.9 kWh an hour ($0.18), 7.2 kWh a day ($1.44) and 7.2 × 365 ÷ 12 = 219 kWh in an average month ($43.80).
The first row is the cost of that schedule if the compressor never rests. The second shows how an effective power percentage changes the result, but 60% here is just an example. Only use a percentage you have a reason for, such as a measurement.
Getting a better number
For a plug-in window or portable unit, a plug-in electricity monitor rated for its current records the kWh it uses over a day or a week of normal use. Central and wired-in systems need meter or smart-meter readings instead; how to measure real appliance electricity use explains both. Then enter the measured figures, or your own input, hours and effective power, in the air conditioner running cost calculator, which also gives an estimate for a cooling season of the length you choose.
Related guides
- Rated power vs actual electricity use: what's the difference?
- Fan, oil-filled, convector or infrared: does the heater type change electricity use?
- How to measure real appliance electricity use
- All guides
Sources
These sources support specific statements on this page. They do not review or endorse this calculator or its results. Last reviewed .
- Natural Resources Canada: Air conditioning your home. Defines capacity as the maximum rate at which an air conditioner removes heat; describes EER and SEER; lists the factors that affect operating cost, including weather, sizing, thermostat setting, habits and door and window openings; advises the highest comfortable setting, shading, sealing and insulation, and cleaning room unit filters at least once each season; and explains that oversized units run short cycles that do not remove humidity well.
- ENERGY STAR: Room air conditioners. Recommends variable-speed compressor technology for better efficiency, sizing to the space, and setting the thermostat as high as is comfortable, typically 78°F; notes that a unit that is too large cools the room before it removes the humidity and that a poorly installed unit leaks air.
- Government of Canada: Energy Efficiency Regulations, 2016, section 108 (room air conditioners). Defines the combined energy efficiency ratio (CEER) for room air conditioners.
- Natural Resources Canada: Heating and cooling with a heat pump. Gives a ton of cooling capacity as 3.5 kW or 12,000 Btu/h and defines EER as Btu/h of capacity divided by watts of electrical input.
- U.S. Department of Energy: Energy Saver Guide (2022, PDF). States that an oversized air conditioner performs less efficiently than a properly sized one, that a ceiling fan allows a thermostat setting about 4°F higher without loss of comfort, and advises cleaning or replacing air conditioner filters monthly or as recommended.
How this guide was written
The first draft was written with the help of an AI writing assistant. It was then edited, every calculation was worked through again, and each factual statement was checked against the sources listed above; statements that could not be checked were removed. Example figures are illustrations chosen to show the arithmetic, not measurements or typical values. See the methodology for how the calculators work.