Methodology
How estimates are calculated, so you can check every result yourself.
Core formula
Energy in kilowatt-hours (kWh) equals power in watts (W) multiplied by hours of use, divided by 1,000. Cost equals energy in kWh multiplied by your price per kWh.
Example: 1,000 W for 1 hour is 1 kWh. At an illustrative price of $0.20 per kWh, 1 kWh costs $0.20.
Step by step: estimating an appliance's cost
- Choose how to describe its energy use. Use a yearly kWh figure for appliances that run all the time, such as refrigerators; energy per cycle for washing machines, dishwashers and dryers; power and hours for heaters, air conditioners, lighting and kettles; and in use plus standby for devices left plugged in.
- Find the figure. Take it from the energy label, the rating plate or the manual (see how to read appliance energy labels), or measure it (see how to measure real appliance electricity use).
- Enter how much you use it: hours a day and days a week, or cycles a week.
- Enter your price per kWh from your bill, in currency units, not cents or pence.
- Read the results per period, and check the working shown under them.
Units
- W (watts) and kW (kilowatts) measure power. 1 kW = 1,000 W.
- kWh (kilowatt-hours) measure energy, which is what electricity is billed by.
- An air conditioner's cooling capacity in BTU/h is not its electrical power. Use its rated electrical input in watts instead.
Time periods
- Per hour of use (power and hours method): power × effective power ÷ 100 ÷ 1,000.
- Per day of use: power × hours used that day ÷ 1,000.
- Week: energy per day of use × days used per week.
- Average calendar day: weekly energy ÷ 7.
- Year: weekly energy × 365 ÷ 7, using a 365-day year.
- Average month: annual energy ÷ 12. A 30-day month is never used.
Calculation methods
Each method produces a weekly figure; the year, average month and average calendar day follow from it as above.
- Power and hours: weekly kWh = watts × effective power ÷ 100 × hours per day × days per week ÷ 1,000. Effective power is 100% unless you change it. Used by the appliance cost calculator, the space heater, the air conditioner and the dehumidifier calculators.
- Energy per cycle: weekly kWh = kWh per cycle × cycles per week. Used by the washing machine, dishwasher and clothes dryer calculators.
- Energy per year: the yearly kWh from the label is used as the year; weekly kWh = yearly kWh × 7 ÷ 365. Used by the refrigerator calculator.
- In use plus standby: weekly kWh = in-use watts × hours in use per week ÷ 1,000 + standby watts × (hours plugged in − hours in use) ÷ 1,000. Plugged-in hours include the hours in use, so no hour is counted twice. Used by the standby power calculator.
Effective power assumption
Appliances with a thermostat, humidistat or compressor, such as air conditioners and dehumidifiers, do not always draw their full rated input. The optional effective power percentage (0 to 100) is your own assumption and is applied as percentage ÷ 100. At 100% the estimate assumes full rated input for every hour entered. No typical percentage is provided. Rated power vs actual electricity use explains duty cycles and when a lower percentage is justified.
Season estimates
The air conditioner calculator can multiply the weekly figure by your weeks of use per year. This season estimate is shown on that page only: it is not saved with the appliance and does not change comparison or dashboard totals. Everywhere else, including the comparison and dashboard, a year means use every week of a 365-day year.
kWh calculator
The kWh calculator solves for energy, average power or time: Energy (kWh) = watts × hours ÷ 1,000; average power (W) = kWh × 1,000 ÷ hours; time (hours) = kWh × 1,000 ÷ watts. Dividing by zero hours or zero watts has no answer, so those inputs must be above 0.
Its volts and amps helper gives power from voltage and current: for DC, watts = volts × amps; for single-phase AC, watts = volts × amps × power factor (0 to 1, using RMS values). Without a power factor it shows the apparent power in volt-amperes (VA) and says that using it as watts assumes a power factor of 1, an upper estimate. Voltage and current are limited to 1,000 V and 1,000 A. Three-phase supplies are not covered.
Estimates from rated power
When only a rated power is known, some pages offer a separate estimate that multiplies it by the whole operating time, which assumes the appliance draws its rated power continuously. Actual power varies by appliance, operating stage and conditions, so for appliances such as washing machines and clothes dryers the result may overestimate actual energy use. It is not a guaranteed upper bound for every appliance, and each such estimate states its assumption. Energy per cycle (clothes dryer page) = watts × cycle minutes ÷ 60 ÷ 1,000. Energy per week (washing machine page) = watts × hours of use per week ÷ 1,000, with the year and average month following from the weekly figure as above: an average month is about 4.35 weeks, not exactly four. These estimates never change the calculator; you copy the figure in.
Totals for several appliances
Totals add up each appliance's weekly, yearly, average-month and average-calendar-day figures. A combined “per day of use” total is not shown, because appliances are used on different days.
Input limits
- Power and standby power: 0 to 100,000 W (100 kW). Hours of use per day: 0 to 24. Days of use per week: 0 to 7.
- Hours plugged in per week: 0 to 168, and at least the hours in use. Effective power: 0 to 100%.
- Energy per cycle: 0 to 50 kWh. Cycles per week: 0 to 100. Energy per year: 0 to 100,000 kWh.
- kWh calculator: time up to 8,760 hours (one year) and energy up to 100,000 kWh.
- Rated-power estimates: up to 100,000 W, cycles up to 1,440 minutes and up to 168 hours of use per week.
- Electricity price: 0 to 100 per kWh. A price of 2 or more triggers a check, because it is often a price in cents or pence entered as whole units. For Russian rubles, whose prices are normally several units per kWh, the check starts at 50.
- Numbers can include decimals (for example 0.5 hours). Negative numbers, exponents and text are rejected.
Currency and rounding
Choosing a currency changes only how amounts are displayed. No exchange rates are applied and no tariffs are looked up. Calculations keep full precision and are rounded only for display: energy to 2 decimal places and money to 2 decimal places. Non-zero values smaller than 0.01 are shown with 2 significant digits instead of 0.00. CSV downloads round energy to 3 decimal places and money to 2.
Sources
The calculator has no built-in appliance wattages or electricity prices: every result comes from the figures you enter. The sources below support specific statements on this site. They do not review or endorse this calculator or its results. Last reviewed .
- U.S. Energy Information Administration (EIA): Measuring electricity. Defines a watthour as one watt used for one hour and a kilowatt as 1,000 watts, and notes that utilities generally measure electricity in kilowatthours. This supports the unit conversion energy (kWh) = watts × hours ÷ 1,000.
- Federal Trade Commission (FTC): Energy Labeling Rule. Requires EnergyGuide labels on products including refrigerators, clothes washers and room air conditioners, showing an estimated yearly operating cost and the model's energy use or efficiency. This supports entering a label's yearly kWh with the energy per year method.
- Electronic Code of Federal Regulations: 16 CFR Part 305 (Energy Labeling Rule). Sections 305.14, 305.15 and 305.18 require refrigerator, clothes washer and room air conditioner labels to state that the estimated cost is based on a national average electricity cost in cents per kWh. Washer labels also assume six loads a week, and room air conditioner labels assume 8 hours of use a day over a 3-month season. This is why a label's cost can differ from your estimate at your own price and use.
- ENERGY STAR: Clothes dryers key product criteria. Defines Combined Energy Factor (CEF) as the weight of a standard test load in pounds divided by the energy used, including standby, in kWh, with a higher CEF meaning a more efficient dryer, and sets separate minimum CEF levels for gas and electric dryer types. This supports the CEF explanation on the clothes dryer page. CEF is not converted into kWh per load anywhere on this site.
- ENERGY STAR: Clothes dryers. Linked from the clothes dryer page as a starting point for information on ENERGY STAR certified dryers. No figures from it are used in any calculation.
- ENERGY STAR: Dishwashers key product criteria. Sets maximum rated energy use for certification of 240 kWh a year for standard dishwashers and 155 kWh a year for compact models, including standby energy, measured with a U.S. Department of Energy test. This supports the ENERGY STAR limits described on the dishwasher page, which are certification maximums, not real-world use.
- ENERGY STAR: Dishwashers. Linked from the dishwasher page as a starting point for information on ENERGY STAR certified dishwashers. No figures from it are used in any calculation.
- ENERGY STAR: Dehumidifiers. Says ENERGY STAR dehumidifiers have a built-in humidistat and cycle on and off to hold the humidity set, measures efficiency as the Integrated Energy Factor in litres per kWh, and gives a 30% to 50% humidity range. This supports the explanation on the dehumidifier page (checked 1 November 2026); no figure from it is used in any calculation.
- EIA: State electricity profiles. Publishes average retail electricity prices by state in cents per kWh. It is linked next to the price field for comparison only; no price from it is used in any calculation.
The 365-day year, average month, average calendar day, effective power option and input limits are this site's own conventions, explained above. They are not taken from these sources. Appliance pages and guides that describe energy labels in Canada, the UK, the EU, Australia and New Zealand list their own official sources.